Aplicatie Flask + SQLite pentru productie alimentara: cantarirea componentelor unui produs finit si tiparirea etichetei prin QZ Tray. - produse finite (retete) formate din componente cantarite - designer vizual de etichete (mm/px, zona sigura, campuri variabile, cod QR cu continut din mai multe bucati) - legare produs finit -> sablon de eticheta - navigare pe doua taburi: Cantarire / Setari - administrare: componente, produse finite, sabloane, campuri, istoric - backup, resetare baza de date, checklist de pregatire, /healthz - CLI de administrare si serviciu systemd pentru productie - vendor/syncpulse-scale-bridge (GPL-3.0-or-later) pentru citirea cantarului
3.3 KiB
3.3 KiB
Changelog
1.1.2 — 2026-10-13
- Platform-neutral wording: the control page, command line, README and package metadata describe the bridge
for any system that needs a weight; the Connect tab is now Network access and shows the request to send
(
GET /weight?profile=…withX-Bridge-Token).
1.1.1 — 2026-10-11
- Fix: a continuous format whose frames are closed only by the start of the next one (XK3190 / YH-T7E
=081.100=081.100…) was not read by/weightwhen the indicator pauses between frames, so that every frame arrives on its own — detection found it, the live reading did not. Each chunk is now read together with the end of the previous one. xk3190_reversedfield-tested on a Yaohua YH-T7E indicator (9600 8N1, about nine frames a second).
1.1.0 — 2026-10-11
Scales that send only when their Print key is pressed — typically indicators wired to a label printer.
- New protocol
label_print: reads the label an indicator sends to its label printer — TSPL/TSPL2 (TSC and compatibles), EPL2 (Zebra/Eltron, Argox) and ZPL (Zebra). The weight is the number printed with a weight unit; the other values on the label (order number, shift, date, time, thickness …) come along asfields. Field-tested on a PTC400 indicator printing to a TSC printer (TSPL, 9600 8N1). - Auto-detection: new wait for Print option (
--wait-print SECONDS) holds the port open until the operator presses Print, steps to the next speed if the data is unreadable, and reads 7E1/7O1 from a single press; new listen only option (--listen-only) never sends a byte to the device. - The bridge keeps the ports of such scales open all the time and records every printed label: the last 500 in
memory (
GET /labels?profile=…&after=SEQ) and a dailylabels/<profile>-YYYY-MM-DD.jsonlfile. /weightanswers includefieldsandon_print; a print-only scale answers at once ("waiting for the Print key") instead of holding the caller.- The control page shows the last printed label, its fields and a short label history.
1.0.0 — 2026-10-01
First public release.
- Automatic detection of the port, speed, framing (8N1, 7E1, 7O1 …) and protocol, with quick and thorough modes, confidence score, raw samples and a cancel button. Read-only requests only.
- Protocol library: Mettler Toledo MT-SICS and Toledo Continuous, A&D, SMA, NCI 3835, Ohaus, Sartorius SBI, CAS (experimental), XK3190 (tF=0 and reversed stream), Mahak MDS (field-tested), generic text, custom binary and custom text formats.
- Saved scale profiles and a parsed-weight API:
GET/POST /weightwith value, unit, stability, net/gross, overload, age and checksum result; unit conversion. - Compatible with SyncPulse Serial Bridge 1.x (
/health,/ports,POST /read,bridge.json). - Bilingual control page (English/Persian): live weights, auto-detection, connection details, access key, allowed clients, raw monitor with protocol guesses, protocol library, about.
- One-click Windows Firewall rule and start-with-Windows task (SYSTEM, no 72-hour limit, restart on failure), both with a UAC prompt.
- Single-file Windows program with version information; single-instance start that opens the running copy.
- Simulated scales for every protocol (
--simulate) and a test suite that needs no hardware.